Basis for intelligent energy management = know the volumetric flow requirement of compressed air. Optimal dimensioning of systems by recognizing potential savings, possible overloads or malfunctions. At the same time, it shows how much compressed air is lost in the system due to leakage.
Volume flow measuring and balancing system FC-1 CA for mobile and stationary use:
Single devices FC1-CA, sensors, measuring adapter
Complete encoders FC-1-M 1 ... 4
FC1-CA the cheap disfiguring system / unique online leak monitoring system with measuring function
Complete measurement paths
The flow measuring system for cost-effective online measurement of branch lines and supply lines for machines and plants. Volume, peak and leakage determination in online procedure, consisting of:
the sensor operating on the calorimetric measuring principle
a defined measuring adapter depending on the required nominal diameter
a separate digital evaluation with connection cable
Measuring range:
Plug-in sensor in the measuring adapter or measuring ball valve
½ ": 0 - 61 Nm³ / h
¾ ": 0 - 101 Nm³ / h
1 ": 0 - 165 Nm³ / h
1¼ ": 0 - 263 Nm³ / h
1¼ ": 0 - 465 Nm³ / h
2 ": 0 - 716 Nm³ / h
insertion sensor
DN 65 ..... DN 1000: 0 .... 120000 Nm³ / h
Media:
Compressed air and gases, filtered and non-condensing
nitrogen
oxygen
argon
carbon dioxide
Measured variable: standard flow in Nm³ / h, normal consumption in Nm³, related to normal conditions
Sensor material: Stainless steel 1.4571 electropolished
Measuring accuracy: +/- 3% of the measured value, max. +/- 1% of the full scale value
Reproducibility: max. +/- 0.5% of the full scale value
Operating temperature: -20 to +60 ° C optional: up to + 120 ° C
Operating pressure: 0 ... 16 bar optional: 0 ... 100 bar
Inlet section: 10 x D
Outlet section: 5 x D
Evaluation electronics: LED display, 5 digits, installed in the field housing
Degree of protection IP 65, front jet proof and dustproof
Current measured value is very easy to read on the front panel even in dark surroundings
Minimum and maximum value as well as the consumption sum are stored and can be called or reset via a roll function.
Power supply: 85 - 240 VAC, 50-60 Hz, power supply of the sensor (24VAC) is integrated
Housing: impact-resistant plastic
TECHNICAL DATA FLOWCONTROL FC2
The new cost-effective volume measuring system for terminal measurement:
Flow rate, maximum amount, leakage message, total consumption
Terminal power balancing / online leakage monitoring
Volumetric flow meter FC-2 for ½ "to 2" pipe sizes
The flow measuring system for cost-effective online measurement of branch lines and supply lines for machines and plants. Volume, peak and leakage determination in online procedure, consisting of:
the sensor operating on the calorimetric measuring principle
a defined measuring adapter depending on the required nominal diameter
a separate digital evaluation with connection cable
Measuring range:
½ ": 0 - 61 Nm³ / h
¾ ": 0 - 101 Nm³ / h
1 ": 0 - 165 Nm³ / h
1¼ ": 0 - 263 Nm³ / h
1¼ ": 0 - 465 Nm³ / h
2 ": 0 - 716 Nm³ / h
Media: compressed air, filtered and non-condensing (other gases on request)
Measured variable: standard flow in Nm³ / h, normal consumption in Nm³, related to standard conditions
Sensor material: brass, ceramic / polyamide
Measuring accuracy: +/- 3% of the measured value, max. +/- 1% of the full scale value
Reproducibility: max. +/- 0.5% of the full scale value
Operating temperature: -20 to +60 ° C
Operating pressure: 0 to 16 bar
Inlet section: 15 x D
Outlet section: 5 x D
Evaluation electronics: LED display, 5 digits, installed in the field housing
Degree of protection IP 65, front jet proof and dustproof
Current measured value is very easy to read on the front panel even in dark surroundings
Minimum and maximum value as well as the consumption sum are stored and can be called or reset via a roll function.
Power supply: 85 - 240 VAC, 50-60 Hz, power supply of the sensor (24VAC) is integrated
Housing: impact-resistant plastic
You can "retrofit" the volume flow meter FC-2 and react flexibly to future requirements. Just plug in an option board and set the new parameters via the front panel and the device goes into extended use.
Reduce costs through consumption-based cost allocation and leak detection. With the flow detection and their totalization, a consumption-dependent allocation of expensive compressed air is possible. For most operators of compressed air systems, the leakage losses are over 30%. Here, the strength of the calorimetric flow measurement can be used to reliably measure even very small volume flows and leakage losses.
The simple plug-in system of the sensors allows the use in any sensor adapter or measuring ball valve of 1/2 "to 2" pipe diameter. By simply reprogramming the evaluation electronics, leaks can be detected and closed in a first step, in a second step the same measuring system can then be used for consumption measurements.
With our measuring systems FlowControl FC1 and FlowControl FC2 we actively contribute to cost transparency. The FlowMonitors are used for precise consumption recording in the industrial use of compressed air, because only the compressed air energy balance creates transparency in controlling. This is the only way for everyone to realize the not inconsiderable costs for compressed air. It will be more responsible and therefore more economical to deal with this energy source as soon as the energy used can be assigned to the consumer cost centers.
An example is intended to illustrate the financial consequences of a very small, imperceptible leakage:
1mm² leakage area corresponds to a power loss for the compressor of 1,7KW = 10 m³ / h
Operating air costs: 0.025 € / m³ (average value)
Minimum cost per year due to this leakage: 2010 €
335 days x 24 hours x 10 m³ x € 0.025 = 2010 €
With our FlowControl systems we help you to save costs!